Current drawn by 1000 W on this supply
| Voltage | Amps for 1000 W |
|---|---|
| 120 V | 8.33 A |
| 208 V | 4.81 A |
| 230 V | 4.35 A |
| 240 V | 4.17 A |
Solve for watts, amps or volts from the other two, for DC, single-phase or three-phase AC with power factor, with a quick table for 1000 W.
| Voltage | Amps for 1000 W |
|---|---|
| 120 V | 8.33 A |
| 208 V | 4.81 A |
| 230 V | 4.35 A |
| 240 V | 4.17 A |
Power, voltage and current are tied together by one relation. For DC it is watts = volts × amps. For single-phase AC the real power is also scaled by the power factor, which says how much of the volt-amps does useful work. For three-phase AC, with the voltage measured between two lines, the factor 1.732 (the square root of 3) is added.
Pick what you want to find, enter the other two values and the supply type. The same relation is turned around: amps = watts ÷ (volts × power factor), and volts = watts ÷ (amps × power factor). Use a power factor of 1 for resistive loads such as heaters, kettles and incandescent lamps. Motors, compressors and many switch-mode power supplies sit between 0.8 and 0.95.
The table under the answer shows what 1000 W draws at common voltages on the supply you picked, so you can scale it for any load: 3000 W draws three times as much. The second panel is Ohm's law. Give any two of voltage, current, resistance and power and it returns the other two.
Check it by hand: on single-phase AC, amps = watts ÷ (volts × power factor). For 1,000 W at 120 V with a power factor of 1, that is 1,000 ÷ 120 = 8.33 A. With Ohm's law, 12 V across 2 A means a resistance of 12 ÷ 2 = 6 ohm and a power of 12 × 2 = 24 W.
DC: P = V × I Single-phase AC: P = V × I × PF Three-phase AC (line-to-line V): P = 1.732 × V × I × PF Ohm's law: V = I × R, P = V × I = I² × R = V² ÷ R P in watts, V in volts, I in amps, R in ohms, PF is the power factor (1 for DC). Source: Ohm's law and the standard AC power relations (IEEE Std 1459 defines active, reactive and apparent power).
A 1000 W heater on a 120 V single-phase supply, power factor 1: amps = 1000 ÷ 120 = 8.33 A. On a 230 V supply the same heater draws 1000 ÷ 230 = 4.35 A.
A three-phase motor load of 10,000 W at 400 V line to line with a power factor of 0.8: amps = 10,000 ÷ (1.732 × 400 × 0.8) = 18.04 A.
Multiply amps by volts and divide by 1,000. For a single-phase load with power factor 1, 20 A at 230 V is 4.6 kW, and at 120 V it is 2.4 kW. For three-phase, multiply by 1.732 and by the power factor: 20 A at 400 V and a power factor of 0.8 is about 11.09 kW.
Divide the watts by the volts. For 1000 W at 120 V that is 8.33 A, and at 230 V it is 4.35 A. For AC loads with a power factor below 1, divide by volts × power factor instead. For three-phase, divide by 1.732 × volts × power factor.
Multiply the amps by the volts. 10 A at 120 V is 1200 W, and 10 A at 230 V is 2300 W. For AC, also multiply by the power factor, and by 1.732 for three phase.
It depends on the voltage. At 12 V, 1 A is 12 W. At 120 V it is 120 W and at 230 V it is 230 W, assuming a power factor of 1.
Divide the watts by the amps. A 24 W load drawing 2 A is on 12 V. Choose "Volts" in the first panel and enter the watts and amps.
Power factor is real power divided by apparent power (volt-amps). Use 1 for heaters, kettles and incandescent lamps. For motors and unknown AC equipment, 0.8 is a cautious choice, and the equipment label often shows the actual value.
Only when the AC power factor is 1. A load with a lower power factor draws more amps for the same watts, which is why the AC modes ask for it.
Voltage equals current times resistance (V = I × R). Power is voltage times current, which also equals I² × R and V² ÷ R. The second panel solves all four from any two.
At power factor 0.8, amps = 5,000 ÷ (1.732 × 400 × 0.8) = 9.02 A. Choose three-phase AC (line to line) as the supply and enter the power factor from the equipment label.
Part of the guide: Electrical, power and solar calculators: amps, wire size, generators and batteries