Water Heater Size Calculator

The kW and BTU a tankless water heater needs for the taps running at once, and the tank size for a storage heater.

Tankless (instant)

Typical flow 2 gpm (7.6 L/min) each.

Typical flow 1.5 gpm (5.7 L/min) each.

Typical flow 1 gpm (3.8 L/min) each.

Typical flow 1.5 gpm (5.7 L/min) each.

Typical flow 2 gpm (7.6 L/min) each.

°C

Cold water from the mains. It can be near freezing in a cold climate in winter, which raises the power needed a lot.

°C

49 °C is the usual setting for taps and showers.

%

Electric heaters are close to 100%. Gas models list a lower figure on the rating plate.

V

Only used for the current in amps, for example 230 or 240.

Heater power needed

31.4 kW

or 107,100 BTU per hour

Flow rate
3.5 gpm (13.2 L/min)
Temperature rise
34 °C (61.2 °F)
Heat into the water
31.4 kW
Power at the heater input
107,100 BTU per hour
Current if electric, single phase
137 A at 230 V

3.5 gpm (13.2 L/min) heated by 34 °C needs a tankless water heater of about 31.4 kW.

Storage tank

20 gallons (76 L) per use in the US Department of Energy worksheet.

2 gallons (8 L) per use in the US Department of Energy worksheet.

3 gallons (11 L) per use in the US Department of Energy worksheet.

7 gallons (26 L) per use in the US Department of Energy worksheet.

25 gallons (95 L) per use in the US Department of Energy worksheet.

15 gallons (57 L) per use in the US Department of Energy worksheet.

Storage tank size (estimate)

40 to 50 gallons

for 4 people, or 151 to 189 litres

Tank size in litres
151 to 189 L
Peak hour demand
52 gallons (197 L)
Look for a first hour rating of at least
52 gallons

A household of 4 usually fits a 40 to 50 gallon tank, and a busy hour of 52 gallons needs a model with a first hour rating of at least 52 gallons.

Add this calculator to your website

Free to use on any site or blog. Paste this code where you want the calculator to appear. It stays up to date, needs no account, and keeps your visitors' numbers in their own browser.

Preview

How it works

A tankless (instant) water heater heats water as it flows, so its power has to cover the busiest moment. The calculator adds up the flow of every fixture that can run together, takes the rise from the cold incoming temperature to the temperature you want, and works out the heat needed. In South Asia the same appliance is called a geyser, and the same sums apply to an instant geyser.

The typical flows used are 2.0 gpm (7.6 L/min) for a shower, 1.5 gpm for a kitchen faucet, 1.0 gpm for a bathroom faucet, 1.5 gpm for a dishwasher and 2.0 gpm for a washing machine. Change the number of each to match your home. The US Department of Energy advises at least 3.25 gpm (12.3 L/min) for a tankless heater, and assumes cold water at 50 °F (10 °C) and a target of 120 °F (49 °C).

Heat needed is flow times the specific heat of water times the rise. In metric units one litre of water weighs 1 kg and needs 4.186 kJ per degree, so kW = L/min × 4.186 × rise in °C ÷ 60. In US units a gallon weighs 8.33 lb, one BTU warms one pound by 1 °F, and there are 60 minutes in an hour, so 8.33 × 60 = 499.8, rounded to the well known 500: BTU per hour = 500 × gpm × rise in °F. The two forms agree to within about 0.2%.

The second tab is for a storage tank. It gives a tank size from the number of people, using the common rule of thumb of 30 to 40 gallons for 1 to 2 people, 40 to 50 gallons for 3 to 4 people and 50 to 80 gallons for 5 or more. It also adds up your peak hour demand with the US Department of Energy worksheet (20 gallons for a shower, 2 for a shave, 3 for hand dishwashing, 7 for a dishwasher, 25 or 15 for a clothes washer). Pick a heater whose first hour rating is at least that number.

Check it by hand: the default flow is 3.5 gallons a minute, which is 13.25 L/min. Water at 15 °C heated to 49 °C is a rise of 34 °C. The heat is 13.25 × 4.186 × 34 ÷ 60 = 31.4 kW. In BTU, the rise is 61.2 °F, so 500 × 3.5 × 61.2 = 107,100 BTU per hour. On a 230 V supply the current is 31,400 ÷ 230 = 137 A.

kW = L/min × 4.186 × ΔT(°C) ÷ 60     (specific heat of water 4.186 kJ/kg·K)
BTU/h = 500 × gpm × ΔT(°F)     (500 = 8.33 lb/gal × 60 min/h × 1 BTU/lb·°F, rounded)
Input power = heat into the water ÷ efficiency
Amps = watts ÷ volts
First hour rating needed ≥ peak hour demand (US Department of Energy worksheet)

Worked example

One shower (2.0 gpm) and one kitchen faucet (1.5 gpm) run together: 3.5 gpm, which is 13.25 L/min. The water comes in at 15 °C and leaves at 49 °C, a rise of 34 °C (61.2 °F).

kW = 13.25 × 4.186 × 34 ÷ 60 = 31.4 kW. In BTU: 500 × 3.5 × 61.2 = 107,100 BTU per hour. At 230 V that is about 137 A, far more than most homes can supply on a single circuit, which is why electric whole-house tankless heaters often need three phase or a lower flow, and why many people size for one shower only.

Good to know

  • This is an estimate. Heater makers publish a flow they can deliver at a given rise, and that curve is what you should check. Buy by the maker's table, not by this number alone.
  • In cold climates the incoming water can be 5 °C (41 °F) or less in winter. A bigger rise needs more power or a lower flow, so run the numbers with your coldest month, not the average.
  • The household rule of thumb for tank size is a common retail and plumbing guide, not a US Department of Energy table. The Department of Energy method is the first hour rating against peak hour demand, shown in the second result.
  • Pipe length, recirculation loops, water softeners, low pressure and fixture flow limits are not included. A licensed plumber or electrician must size the supply, gas line and breaker.

Questions people ask

What size tankless water heater do I need?

Add the flow of the fixtures that run at once, find the temperature rise, and use kW = L/min × 4.186 × rise ÷ 60. One shower at 2.0 gpm with a 34 °C rise needs about 18 kW, and two showers about 36 kW.

How do I size a geyser?

The method is the same as for any instant water heater: the flow of the taps you want to run together and the rise from your cold water temperature to the hot setting. A storage geyser is sized by litres instead, using the second tab.

What size water heater tank do I need for 4 people?

A common rule of thumb is 40 to 50 gallons (150 to 190 L) for 3 to 4 people. Check that the first hour rating is at least your busiest hour of hot water use.

What is the 500 in the BTU formula for water heaters?

A gallon of water weighs 8.33 pounds, one BTU raises one pound by 1 °F, and there are 60 minutes in an hour. 8.33 × 60 × 1 = 499.8, which is rounded to 500.

Why does cold weather change the heater size?

Colder mains water needs a bigger temperature rise to reach the same hot temperature. Power rises in direct proportion to the rise, so water at 5 °C needs more power than water at 15 °C for the same flow.

How many kW does it take to heat 10 L/min of water by 30 °C?

10 × 4.186 × 30 ÷ 60 = 20.93 kW.

Part of the guide: Heating, cooling and water calculators: BTU, pipes, tanks, pumps and pools

Formulas and text last checked on 7 October 2026. Everything is calculated in your browser, so nothing you enter is sent or stored. Spotted a mistake? Tell us and we will fix it.