Rainwater Harvesting Calculator

The rainwater a roof can collect per year and per month from the catchment area and rainfall, and the tank size for a number of dry days.

m²

The footprint the rain falls on, measured flat from above. Do not use the sloped surface.

mm

The yearly average for your area, from a local weather service.

Typical published runoff coefficients: the share of rain that runs off instead of soaking in, evaporating or splashing out.

%

Water lost to the first-flush diverter, the filter and overflow. 90% is a common allowance.

L

What you want to take from the tank. Leave empty to skip the tank size.

The longest spell with little or no rain where you live.

Water collected per year (estimate)

64,800 L

5,400 L a month on average, 17,118 US gal per year

Collected per year
64,800 L (17,118 US gal, 64.8 m³)
Average per month
5,400 L (1,427 US gal)
For each 1 mm of rain
81 L (21.4 US gal)
For each 1 inch of rain
2,057 L (544 US gal)
Runoff coefficient and efficiency
0.9 × 0.9
Tank for the dry spell
3,600 L (951 US gal)
Water used per year
43,800 L (11,571 US gal)
Share of yearly use the roof can cover
100% or more

A roof of 100 m² with 800 mm of rain a year collects about 64,800 L a year. To cover 30 dry days at 120 L a day, the tank should hold about 3,600 L.

Add this calculator to your website

Free to use on any site or blog. Paste this code where you want the calculator to appear. It stays up to date, needs no account, and keeps your visitors' numbers in their own browser.

Preview

How it works

Rain falling on a flat area gives one litre for every square metre for each millimetre of rain. So a 100 m² roof in 800 mm of rain receives 80,000 litres in a year. Not all of it reaches the tank, so the calculator multiplies by two factors.

The runoff coefficient is the share that runs off the roof: about 0.9 for metal or tile, 0.85 for asphalt shingle and 0.7 for flat concrete. These are typical published values. The second factor is the efficiency of the first-flush diverter, filter and gutters, 0.9 by default.

In US units, one inch of rain on one square foot is 144 cubic inches, which is 0.623 gallons. The calculator works in metric underneath and shows both.

If you enter your daily use, the tank size is that use times the dry days you want to cover. It also shows how much of your yearly use the roof can supply, so you can see whether the roof is big enough to fill the tank.

To work out the size of a round or rectangular tank for that volume, use the Tank Volume Calculator.

Check it by hand: a roof of 100 m² and 800 mm of rain a year gives 100 × 0.8 = 80 m³, which is 80,000 L before losses. The metal roof runoff coefficient is 0.9 and the filter efficiency is 0.9, so 80,000 × 0.9 × 0.9 = 64,800 L a year. Divided by 12 that is 5,400 L a month. Each 1 mm of rain on the roof gives 100 × 0.9 × 0.9 = 81 L.

Collected water (L) = roof area (m²) × rainfall (mm) × runoff coefficient × efficiency
1 mm of rain on 1 m² = 1 litre
US shortcut: gallons = area (sq ft) × rainfall (in) × 0.623 × runoff × efficiency
Tank (L) = daily use × dry days
Runoff coefficients: metal or tile 0.9, asphalt shingle 0.85, flat concrete 0.7 (typical published values)

Worked example

A roof catchment of 100 m² in a place with 800 mm of rain a year, a metal roof (0.9) and a first-flush and filter efficiency of 90%. Collected water = 100 × 800 × 0.9 × 0.9 = 64,800 litres a year, which is 5,400 litres a month on average.

In US units, 1,000 sq ft and 30 inches of rain give 1,000 × 30 × 0.623 × 0.9 × 0.9 = 15,139 gallons a year with the rounded 0.623 (15,148 gallons with the exact factor). With 120 litres a day to cover 30 dry days, the tank should hold 3,600 litres.

Good to know

  • It uses the yearly average. Rain does not fall evenly, so a month can give far more or less than one twelfth of the year. The tank for a dry spell is a simple use times days figure, not a month-by-month water balance.
  • Use the flat footprint of the roof, measured from above. A sloped roof does not catch more rain than its footprint.
  • Runoff coefficients are typical values. Old, rough or dirty roofs lose more. Check local rules too: some places limit rainwater collection or require a permit.
  • Collected rain from a roof is not drinking water without proper treatment. This tool is only about quantity.
  • The tank also needs an overflow and a safe place to stand. A full tank is very heavy.

Questions people ask

How do I calculate rainwater harvesting from a roof?

Multiply the roof area in square metres by the rainfall in millimetres to get litres, then multiply by the runoff coefficient (about 0.9 for a metal roof) and the filter efficiency (about 0.9). For 100 m² and 800 mm that is 64,800 litres a year.

How many gallons of rain per square foot of roof?

About 0.623 US gallons for each inch of rain, before losses. With a runoff coefficient of 0.9 and filter efficiency of 0.9, it is about 0.50 gallons per square foot per inch.

What runoff coefficient should I use?

Typical published values are 0.9 for metal and tile, 0.85 for asphalt shingle and 0.7 for flat concrete. Green roofs and gravel roofs are lower. The range 0.8 to 0.9 is common for sloped roofs.

What size rainwater tank do I need?

Multiply your daily use by the number of dry days the tank must cover. At 120 litres a day for 30 days that is 3,600 litres. The tank cannot hold more than the roof collects, so check the yearly figure too.

Does 1 mm of rain really equal 1 litre per square metre?

Yes. A square metre is 1,000 mm by 1,000 mm, and 1 mm of depth over it is 1,000,000 mm³, which is exactly 1 litre.

How much water does 1 mm of rain give from a 100 m² roof?

100 × 1 × 0.9 × 0.9 = 81 L, using the metal roof and filter defaults. With no losses it would be exactly 100 L.

Part of the guide: Heating, cooling and water calculators: BTU, pipes, tanks, pumps and pools

Formulas and text last checked on 7 October 2026. Everything is calculated in your browser, so nothing you enter is sent or stored. Spotted a mistake? Tell us and we will fix it.