Furnace Size Calculator

A rule-of-thumb estimate of the heating capacity a home needs, with the furnace input for your AFUE, in BTU per hour and kW.

sq ft

All the floors the furnace heats, not the garage or an unheated basement.

ft

The figures assume 8 ft. Taller rooms scale up in proportion.

%

Annual fuel utilisation efficiency from the label: 80% for a standard furnace, 90% to 98% for a condensing one.

Furnace size (estimate)

93,750 BTU per hour

input, or 75,000 BTU per hour output (22 kW)

Heat the house needs (output)
75,000 BTU per hour (22 kW)
Range for this climate
60,000 to 90,000 BTU per hour
Furnace input at 80% AFUE
93,750 BTU per hour (27.5 kW)
Input range
75,000 to 112,500 BTU per hour
BTU per square foot used
37.5
Next common furnace size
100,000 BTU per hour input

A 2,000 sq ft home in a moderate climate needs about 75,000 BTU per hour of heat, so a furnace with an input of about 93,750 BTU per hour at 80% AFUE. This is a rule of thumb, not a load calculation.

Add this calculator to your website

Free to use on any site or blog. Paste this code where you want the calculator to appear. It stays up to date, needs no account, and keeps your visitors' numbers in their own browser.

Preview

How it works

A furnace must replace the heat a house loses on the coldest days. The proper way to find that is a room-by-room load calculation, but a quick estimate from floor area is widely used for budgeting and for checking a quote. The calculator takes the middle of the usual BTU per square foot range for your climate, then adjusts it for insulation and ceiling height.

The ranges are 40 to 60 BTU per square foot per hour for a cold climate, 30 to 45 for a moderate one and 20 to 35 for a warm one. These are rules of thumb for the heat the house needs (the furnace output). Poor insulation multiplies the figure by 1.2, good insulation by 0.8. Ceiling height is scaled against 8 feet, so a 10 foot ceiling adds 25%.

A furnace wastes some of its fuel, and AFUE says how much. An 80% AFUE furnace turns 80% of the fuel into heat, so for 75,000 BTU per hour of output you need an input of 75,000 ÷ 0.80. The input is the figure on the furnace label, and the result also shows the next common size at or above it. One kilowatt is 3,412 BTU per hour.

Do not use this as the final answer. The standard method in North America is the Manual J load calculation from ACCA (Air Conditioning Contractors of America), which counts every wall, window, and air leak. Ask the contractor for it. Oversizing is a real problem: a furnace that is too big heats the house fast, shuts off early, cycles often, wears out sooner, costs more, and leaves uneven temperatures.

Check it by hand: a 2,000 sq ft house in a moderate climate with average insulation uses 37.5 BTU per hour per sq ft for the heat it needs, so 2,000 × 37.5 = 75,000 BTU per hour of output. A furnace at 80% AFUE turns 80% of its input into heat, so the input is 75,000 ÷ 0.80 = 93,750 BTU per hour. The next common size up is 100,000 BTU per hour input.

Output (BTU/h) = floor area (sq ft) × BTU per sq ft (middle of climate range) × insulation factor × (ceiling height ÷ 8 ft)
Input (BTU/h) = output ÷ (AFUE ÷ 100)
kW = BTU/h ÷ 3,412
Proper sizing: Manual J load calculation (ACCA)

Worked example

A 2,000 sq ft home in a moderate climate (30 to 45 BTU per sq ft, middle 37.5), average insulation, 8 ft ceilings and an 80% AFUE furnace.

Output = 2,000 × 37.5 × 1.0 × 1 = 75,000 BTU per hour, which is 22.0 kW. Input = 75,000 ÷ 0.80 = 93,750 BTU per hour, so the next common furnace size is 100,000 BTU per hour input. The climate range gives 60,000 to 90,000 BTU per hour of output.

Good to know

  • This is a rule-of-thumb estimate. It does not count windows, air leaks, ductwork losses, the shape of the house, or the outdoor design temperature of your town. Two homes of the same size can differ by a factor of two.
  • A Manual J load calculation by a contractor is the right way to size heating equipment. Many codes and utility rebates require it.
  • Do not size up "to be safe". An oversized furnace short-cycles, which reduces comfort and efficiency. A correctly sized one runs longer and more evenly.
  • Furnace sizes are for the heat input of fuel-burning furnaces. Heat pumps and electric furnaces are sized by output, so use the output figure for those.

Questions people ask

What is a Manual J calculation and do I need one?

Manual J is the room-by-room heat loss and heat gain method from ACCA that contractors use to size heating and cooling equipment. It counts wall, window, roof and floor areas, insulation, air leakage and local design temperatures. This calculator is a quick estimate from floor area, so use it to know the range, and ask a contractor for a Manual J before you buy.

What size furnace do I need for a 2,000 square foot house?

In a moderate climate with average insulation, this tool estimates about 75,000 BTU per hour of heat, or 93,750 BTU per hour of input for an 80% AFUE furnace. A Manual J calculation will give the real number for your house.

How many BTU per square foot do I need for heating?

The usual rules of thumb are 40 to 60 in a cold climate, 30 to 45 in a moderate one and 20 to 35 in a warm one. Insulation and ceiling height move the figure up or down.

What is a Manual J load calculation?

It is the standard method from ACCA for finding how much heating and cooling a house needs, room by room, from the size of walls, windows, insulation and air leakage. A contractor runs it with software.

What is the difference between input and output BTU?

Input is the fuel the furnace burns and output is the heat it delivers. Output = input × AFUE. An 80% furnace with a 100,000 BTU input delivers 80,000 BTU per hour.

What happens if a furnace is too big?

It shuts off before the house is evenly warm, so it starts and stops often. That wears the parts, costs more to buy and run, and leaves hot and cold spots.

What input does a 75,000 BTU output need at 95% AFUE?

75,000 ÷ 0.95 = 78,947 BTU per hour, so an 80,000 BTU input furnace is the closest size.

Part of the guide: Heating, cooling and water calculators: BTU, pipes, tanks, pumps and pools

Formulas and text last checked on 7 October 2026. Everything is calculated in your browser, so nothing you enter is sent or stored. Spotted a mistake? Tell us and we will fix it.