Electrical, power and solar calculators: amps, wire size, generators and batteries

Convert watts, amps, volts and kVA, size wire, generators, UPS and batteries, plan solar, and find what appliances cost to run.

Electrical planning comes down to a few relationships between volts, amps and watts, and then a few safety margins on top. The tools below do the arithmetic and show their working, so you can check it against a nameplate or a quote.

They are for planning and understanding the numbers. Wiring, generators and battery systems can cause fires and injuries when done wrong, so have the final design checked by a licensed electrician and follow your local code.

Which tool do I need?

Start from your question.

Volts, amps and watts

Power in watts equals volts times amps for DC. For single-phase AC, multiply by the power factor too: watts = volts × amps × power factor. For three-phase AC it is watts = √3 × line volts × amps × power factor. Rearranged, a 2,300 W appliance at 230 V and a power factor of 1 draws 10 A.

Power factor describes how much of the current does useful work. Heaters are close to 1, while motors and many electronics are lower. kVA is the apparent power the wiring and the supply must carry, and kW is the real power that does the work, so kW = kVA × power factor. Generators and transformers are rated in kVA for this reason.

Wire size, voltage drop and safety margins

A wire must carry the current without overheating (its ampacity) and without losing too much voltage over its length. Long runs need thicker wire even at modest current. The wire size tool shows both the size and the voltage drop in mm² and AWG. Ampacity depends on insulation, temperature and how cables are bundled, so tables in your local code decide the final choice.

Protect every circuit with a correctly rated breaker or fuse that is sized for the wire, not only for the load.

Generators, UPS and inverters

Add up the running watts of everything that must work together, then allow for motors. Motors such as pumps, compressors and air conditioners draw several times their running current for a moment when they start, and the generator has to ride that out. The generator tool adds this starting load and can derate for altitude. A UPS or inverter is sized in VA or watts in the same way, with some spare capacity so it does not run at its limit.

Batteries and backup time

Battery energy in watt-hours is volts times amp-hours, for example 12 V × 100 Ah = 1,200 Wh. Backup time is usable energy divided by the load, and usable energy is less than the label because you should not drain a battery fully and the inverter loses some energy as heat. How much you can use depends on the battery type, so check the maker's datasheet. The battery tool lets you enter these assumptions.

Solar and running costs

Solar output depends on panel power, how many hours of strong sun a day your location gets, and system losses. Work from your real monthly use in kWh from a bill. An appliance's energy is watts × hours ÷ 1,000 in kWh, and cost is that times your own price per kWh. No prices or tariffs are built in, so the results use what you pay.

Convert and measure

Backup power

Solar

Bills and running cost

Terms explained

Volt (V)
The electrical pressure. Mains is commonly 230 V or 120 V.
Amp (A)
The current flowing.
Watt (W) / kW
The rate of using power. 1 kW is 1,000 W.
kWh / unit
The energy of 1 kW running for 1 hour. The unit on an electricity bill.
kVA
Apparent power: volts times amps, before the power factor.
Power factor
The share of apparent power that does useful work, from 0 to 1.
Single-phase / three-phase
The type of AC supply. Homes are usually single-phase and industry three-phase.
Ampacity
The current a wire can carry safely.
Voltage drop
Voltage lost along a wire, which grows with length and current.
Ah / Wh
Amp-hours and watt-hours: battery capacity.
UPS / inverter
Equipment that keeps power on during an outage, or changes DC to AC.

Common questions

How do I convert watts to amps?

Divide watts by volts, and by the power factor too for AC. 2,300 W at 230 V and power factor 1 is 10 A.

What is the difference between kW and kVA?

kW is real power doing work, kVA is the total apparent power. kW equals kVA times the power factor.

How do I choose the right wire size?

Find the current, choose a wire with enough ampacity for it, and check the voltage drop over the length. Then confirm with your local electrical code.

How big a generator do I need?

Add up the running watts of what must run together and allow for motor starting load, then choose a generator above that total. The tool gives kW and kVA.

How long will a battery run my load?

Divide the usable watt-hours of the battery by the load in watts. A 12 V 100 Ah battery holds 1,200 Wh, but only part of that is usable.

How many solar panels do I need?

Start from your monthly kWh, divide by the days and the sun hours for your place, and allow for losses. The solar panel calculator does this and shows the energy an array produces.

How do I find what an appliance costs to run?

Multiply its watts by the hours used, divide by 1,000 to get kWh, and multiply by your price per kWh.

Are these safe for final wiring design?

They are for planning. A licensed electrician must confirm the design against your local code.

See all electrical and energy tools

Last checked 2026-10-15. Spotted a mistake? Tell us and we will fix it.