Water Pump Size Calculator

Size a water pump from flow and total dynamic head, with a pipe friction estimate, and convert pressure in psi, bar or kPa to metres or feet of head.

Pump size

The most water you need at once, for example all taps and the garden together.

m

Vertical height from the water level (the pumping level in a well, after drawdown) to the highest outlet.

bar

For a booster or a pressure tank. 0 if the water simply flows out.

m

mm

The inside diameter, which is smaller than the pipe size on the label.

%

Added to the straight pipe loss. 10 to 30% is a typical allowance for a few bends and valves.

%

Small household pumps are often 30 to 50%, good centrifugal pumps 60 to 80% (typical). The pump curve shows the real value at your duty point.

%

Used for the electrical input. Typical 75 to 92%.

Pump shaft power needed, estimate

0.8411 kW (1.128 hp)

Total head 28.3 m (92.85 ft) at 100 L/min

Static lift
25 m (82.02 ft)
Head for outlet pressure
0 m (0 ft)
Friction loss
3.302 m (10.83 ft)
Total dynamic head
28.3 m (92.85 ft)
Total head as pressure
2.775 bar, 40.25 psi
Flow
100 L/min, 6 m³/h, 26.42 gpm
Water speed in the pipe
1.326 m/s
Hydraulic power (water)
0.4626 kW
Pump shaft power at 55% efficiency
0.8411 kW, 1.128 hp
Electrical input at 85% motor efficiency
0.9895 kW
Next common motor size, typical
1.5 hp (1.119 kW)
Note
Estimate only. It does not replace the pump curve: the supplier or installer picks the pump from the duty point (flow and head) on the curve.

Lifting 100 L/min against a total head of 28.3 m (92.85 ft) needs about 0.8411 kW at the pump shaft with a 55% efficient pump. Estimate only: the pump curve decides.

Pressure and head

Head of water

28.12 m (92.27 ft)

Fresh water, 1 bar = 10.197 m = 33.46 ft, 1 psi = 2.307 ft

Head in metres of water
28.12 m
Head in feet of water
92.27 ft
Pressure in psi
40 psi
Pressure in bar
2.758 bar
Pressure in kPa
275.8 kPa

40 psi of water pressure equals 28.12 m (92.27 ft) of head.

Add this calculator to your website

Free to use on any site or blog. Paste this code where you want the calculator to appear. It stays up to date, needs no account, and keeps your visitors' numbers in their own browser.

Preview

How it works

A pump has to do two things: lift water to where it is needed and push it through the pipe. Both are measured as head, the height of a column of water. Total dynamic head = static lift + friction loss in the pipe and fittings + the pressure you need at the outlet, converted to head. The pressure part is 10.197 m per bar, or 2.307 ft per psi.

The power the water receives is hydraulic power = density × gravity × flow × head. A pump is not perfectly efficient, so the power at its shaft is the hydraulic power divided by the pump efficiency, and the electrical input is higher again by the motor efficiency. The tool shows all three and the next common motor size above the shaft power.

For friction, enter your own figure if you have one from a pipe chart. Otherwise choose the pipe option: it uses the Hazen-Williams equation for the pipe length, inside diameter and material, plus a percentage for fittings and valves. The speed of water in the pipe is shown too. Above about 2 m/s a larger pipe is usually better. The Hazen-Williams calculator gives more detail.

The second panel converts pressure to head and back. It answers "how high will this pressure push water", and the water pressure at a depth: 10.2 m of water is 1 bar.

Check it by hand: total head is the static lift plus the friction loss. With a lift of 25 m and a friction loss of 3.30 m, the head is 28.3 m. A flow of 100 L/min is 0.001667 m³/s. Hydraulic power is 1,000 × 9.80665 × 0.001667 × 28.3 = 462.6 W. At 55% pump efficiency the shaft power is 462.6 ÷ 0.55 = 841 W, or 1.13 hp.

TDH (m) = static lift + friction loss + outlet pressure ÷ (ρ g)
Hydraulic power P = ρ × g × Q × H, with ρ = 1,000 kg/m³, g = 9.80665 m/s², Q in m³/s, H in m, P in watts
Shaft power = P ÷ pump efficiency; electrical input = shaft power ÷ motor efficiency
Friction (Hazen-Williams, SI): h = 10.67 × L × Q^1.852 ÷ (C^1.852 × d^4.8704)
Pressure and head: 1 bar = 100 kPa = 10.197 m of water; 1 psi = 6.8948 kPa = 0.7031 m = 2.307 ft.
Sources: the standard Hazen-Williams equation in SI form; standard gravity and psi from NIST SP 811.

Worked example

Flow of 100 L/min (0.001667 m³/s), static lift of 25 m, no outlet pressure, and 60 m of 40 mm inside diameter PVC pipe (C = 150) with 20% extra for fittings: the straight pipe loses 2.75 m, so with fittings the friction is 3.30 m. Total dynamic head = 25 + 3.30 = 28.30 m. Hydraulic power = 1,000 × 9.80665 × 0.001667 × 28.30 = 463 W.

At 55% pump efficiency the shaft power is 841 W (0.84 kW, 1.13 hp), and at 85% motor efficiency the electrical input is 0.99 kW. The next common motor size above 1.13 hp is 1.5 hp (1.12 kW).

Good to know

  • This is an estimate and does not replace the pump curve. A pump is chosen where the flow and the total dynamic head (the duty point) meet on the manufacturer curve, and the supplier or installer decides.
  • The pump efficiency you enter is the efficiency at the duty point. It is much lower for small or badly matched pumps. Use the value from the curve when you have it.
  • For a well pump, use the pumping water level, after the drawdown at your flow, and add the drop pipe length. Submersible pumps, jet pumps and suction lift (a pump above the water level, limited to a few metres by atmospheric pressure and NPSH) each have their own limits that are not checked here.
  • The calculation is for water at normal temperature. Hot water, other liquids and high altitude change the numbers. Starting current is also higher than the running current, see the motor current calculator.

Questions people ask

How do I calculate the head of a pump?

Add the static lift (vertical height from the water level to the outlet), the friction loss in the pipe and fittings, and the pressure you need at the outlet converted to head (1 bar = 10.197 m, 1 psi = 2.307 ft). The sum is the total dynamic head the pump must deliver at your flow.

How do I size a water pump?

Decide the flow you need, work out the total dynamic head, then the power is flow × head × 9.81 ÷ (3,600 × efficiency) in kW with flow in m³/h and head in m. Then choose a pump whose curve passes through that flow and head, and a motor at least as big as the shaft power. The calculator does the arithmetic and shows the next common motor size.

How many hp pump do I need for a well?

It depends on the depth to the pumping water level, the flow and the pressure. As an example, 100 L/min from a pumping level 25 m below the outlet, with about 3 m of pipe friction and a 55% efficient pump, needs about 1.1 hp at the shaft. Use the pumping level, not the static level, and ask the pump supplier to match the curve.

How do I convert psi to feet of head?

Multiply psi by 2.307. 40 psi is 92.3 ft of head, or 28.1 m. In metric, 1 bar is 10.197 m.

What is the water pressure at a given height or depth?

Every metre of water gives 9.80665 kPa, which is 0.098 bar, and every foot gives 0.433 psi. A tank 20 m above the tap gives about 2 bar at the tap, less the friction loss while water flows.

What size booster pump do I need?

Enter the flow you need at peak use, the height to the highest outlet and the pressure you want at it. The tool adds the friction in your pipe. A household booster usually needs 1.5 to 3 bar (about 22 to 44 psi), and the supplier checks the pump curve.

Is a larger pump always better?

No. A pump that is too large for the system runs off its best point, wastes energy and can stress the pipe. Choose the pump whose curve gives your flow and head near its best efficiency point.

How many metres of water head is 40 psi?

40 × 0.7031 = 28.12 m, which is 2.76 bar.

Part of the guide: Heating, cooling and water calculators: BTU, pipes, tanks, pumps and pools