Solar Battery Size Calculator

kWh

Units (kWh) per day from your bill divided by the days, or from the appliance calculator.

days

Days the battery must carry the load with no sun at all. 1 to 3 is common for home systems.

Use what your inverter or charge controller requires. Larger systems use 48 V.

Usable depth of discharge is typically about 50% for lead-acid, and 80 to 90% for LiFePO4. Your battery data sheet gives the figure that keeps the rated life.

%

Typical: 85 to 95% for the inverter plus battery and wiring losses. The inverter data sheet shows its own figure.

Ah

V

12 for a 12 V battery (12.8 for LiFePO4 is fine), 6 for a golf cart battery, 2 for a cell.

h

Your own site value. Use a solar map for your location or your installer's figure. Winter is lower than the yearly average.

Heat, dust, wiring and charge-controller losses. 0.7 to 0.8 is typical.

W

W

Fills the inverter size. Motors and compressors need extra for starting.

Battery bank needed

11.11 kWh

463 Ah at 24 V, or 6 batteries of 200 Ah

Energy to cover
5 kWh (5 kWh a day × 1 days)
Battery energy needed
11.11 kWh
Battery capacity needed at 24 V
463 Ah
Batteries in series
2
Strings in parallel
3
Total batteries
6 of 200 Ah, 12 V
Installed battery bank
14.4 kWh, 600 Ah at 24 V
Panel power needed
1,481 W
Panels of 400 W
4 panels, 1.6 kW

To run 5 kWh a day for 1 day(s) of autonomy with 50% depth of discharge, you need about 11.11 kWh of battery: 6 batteries of 200 Ah and 12 V, and about 4 panels of 400 W.