Units (kWh) per day from your bill divided by the days, or from the appliance calculator.
Days the battery must carry the load with no sun at all. 1 to 3 is common for home systems.
Use what your inverter or charge controller requires. Larger systems use 48 V.
Usable depth of discharge is typically about 50% for lead-acid, and 80 to 90% for LiFePO4. Your battery data sheet gives the figure that keeps the rated life.
Typical: 85 to 95% for the inverter plus battery and wiring losses. The inverter data sheet shows its own figure.
12 for a 12 V battery (12.8 for LiFePO4 is fine), 6 for a golf cart battery, 2 for a cell.
Your own site value. Use a solar map for your location or your installer's figure. Winter is lower than the yearly average.
Heat, dust, wiring and charge-controller losses. 0.7 to 0.8 is typical.
Fills the inverter size. Motors and compressors need extra for starting.
Battery bank needed
11.11 kWh
463 Ah at 24 V, or 6 batteries of 200 Ah
To run 5 kWh a day for 1 day(s) of autonomy with 50% depth of discharge, you need about 11.11 kWh of battery: 6 batteries of 200 Ah and 12 V, and about 4 panels of 400 W.
Solar Battery Size Calculator by Ivorytool, free tools that run in your browser.