Retaining Wall Calculator

Market

Wall type

Wall

Soil and loads

Section

Cost

Engineer requiredEngineered design and permit required: retained height over 4 ft (IRC R404.4 / IBC §1807.2).
Sliding
1.65need 1.5 · Pass
Overturning
3.84need 1.5 · Pass
Bearing
828 psfallowed 2,500 psf · Pass
Eccentricity
2.8 inInside the middle third, no tension · Pass
Ka (Rankine)
0.333
Soil thrust
720 lb/ft
Total horizontal
720 lb/ft
Overturning moment
1,440 lb-ft/ft
Vertical load
2,383 lb/ft
Resisting moment
5,536 lb-ft/ft
Base width B
3.9 ft
Resultant from toe
1.72 ft
Dimensions used
Base width: 3.9 ft · Toe: 11.7 in · Heel: 23.3 in · Stem at base: 11.8 in · Top thickness: 7.9 in · Base slab: 11.8 in · Buried depth: 0 ft · Approx. steel: 12.8 lb/ft

IRC R404.4 / IBC §1807.2: Sliding and overturning at least 1.5 (overturning 1.1 with seismic loads), bearing within the allowable pressure.

  • Global slope stability must be checked by a geotechnical engineer for walls on slopes or soft soil.

Cross-section and pressure diagram

Sliding 1.65 PassOverturning 3.84 PassBearing 828 psf Pass
Pa 720 lb/ftΣV 2,383 lb/ftR6 ftB = 3.9 ftFront

Cross-section of a Cantilever RC wall, 6 ft high. Horizontal thrust 720 lb/ft. Sliding FoS 1.65, overturning FoS 3.84, bearing 828 psf. Engineer required.

Material takeoff

Per your wall length. Rebar is approximate: the final design is by an engineer.

ItemQuantityCost
Concrete6.33 CY$ 1,012
Rebar (approx.)257 lb$ 231
Base gravel1.78 CY$ 80
Drainage gravel6.67 CY$ 301
Perforated pipe 4 in / 100 mm20 ft$ 24
Filter fabric234 sq ft$ 82
Excavation (with 25% fluff)2.91 CY–
Backfill16 CY–
Gravel by weight11.82 tons–

Cost estimate

Materials estimate (placeholder prices)$ 1,730
Installed cost range (materials and labour)$ 4,200 – $ 7,200
Engineer design fee$ 500 – $ 2,000
Permit fee$ 200 – $ 1,000
Total range$ 4,900 – $ 10,200
Per ft of length$ 245 – $ 510
Per sq ft of face$ 41 – $ 85

A preliminary design aid for planning. Rigid body checks, approximate steel and placeholder prices. Final design must be verified by a licensed engineer and your local code.

Step by step working

The calculation with your numbers.

  1. Ka = tan²(45° − φ/2) = (1 − sin φ) ÷ (1 + sin φ) with φ = 30° gives 0.333.
  2. Soil thrust Pa = ½ × K × γ × H² = ½ × 0.333 × 120 pcf × 6 ft² = 720 lb/ft.
  3. Total horizontal ΣH = 720 lb/ft. Overturning moment about the toe = 1,440 lb-ft/ft.
  4. Vertical load ΣV = 2,383 lb/ft from the wall, base and soil on the heel. Resisting moment about the toe = 5,536 lb-ft/ft.
  5. Overturning FoS = 5,536 lb-ft/ft ÷ 1,440 lb-ft/ft = 3.84, needed 1.5: Pass.
  6. Sliding FoS = μ × ΣV ÷ ΣH = 0.5 × 2,383 lb/ft ÷ 720 lb/ft = 1.65, needed 1.5: Pass.
  7. Resultant at 1.72 ft from the toe, e = B/2 − x = 0.23 ft, B/6 = 0.65 ft. q max = 828 psf, allowed 2,500 psf: Pass.
  8. Takeoff for 20 ft of wall: concrete 6.33 CY, rebar (approx.) 257 lb, base gravel 1.78 CY, drainage gravel 6.67 CY, perforated pipe 4 in / 100 mm 20 ft, filter fabric 234 sq ft.
  9. Cost: $ 4,200 to $ 7,200 installed, $ 4,900 to $ 10,200 with fees.

Retaining Wall Calculator by Ivorytool, free tools that run in your browser.